In this section installers with an interest in our Cell String Optimizer technology can find all information about our technology and applications. Please refer to our contact page if there are any further questions.
Please browse our FAQ for all questions regarding our Cell String Optimizer. This section focusses on question from installers and solar professionals.
Where the currently available optimizer systems optimize the system on module level, taylor electronics individually optimize the performance of solar cells, resulting in up to 20% more power.
Safe voltage
taylor. modules only provide power when necessary, following Sunspec protocol. If you power down the gateway, your solar panel will only produce 1 volt per panel. This also means that during installation or maintenance, the solar panels are completely safe.
Less MC4 connectors needed
With integrated CSO’s less MC4 connectors are needed, which lowers install costs & risk of installation mistakes.
Overtemperature
Overtemperature protection and module-level shutdown lowers (fire) risk.
For the full installation instructions please download our quick guide, which you can find here.
Click on below link for the download location:
You can find all important documentation for taylor installation & use by clicking this link.
In a taylor system you can only use compatible inverters, tested and approved by taylor. In the taylor.planner, in the tab "design" you can select the drop down menu under "type inverter" for the full list of compatible inverters.
See below a general overview of compatible inverters:
Solis
Goodwe
Fox
AEG
Yes, it is possible to use multiple stings with one gateway. In this case, take 1 DC cable of both and route them through the gateway. Please note that you cannot connect 2 strings on 1 MPPT on your inverter. For 2 strings use 2 seperate MPPT connections on your inverter. E.g. string 1 to MPPT 1 and string 2 to MPPT 2.
For more information please check the quick guide which you can download here.
Below table shows information on the amount of panels you can or should use per MPPT on your inverter. Maximum amount of panels is depended on your maximum input voltage of your inverter, minimum amount of panels needed is depended on your minimum MPPT voltage.
Note that:
*all systems and environments are unique, below is a guideline which needs adjustment per case. In case of any doubt contact our support department, we are happy to help.
* The above numbers are based on corrected Standard Test Conditions (STC) values > (STC: 1000W/m2 & 25C)
* For the maximum voltage scenario, the total system voltage is calculated at -15C.
* For the minimum voltage scenario, the total system voltage is calculated at +80C.
Reach out to us if you need any assistance
Here you can find an overview of all our downloads such as manuals and declarations. Reach out to us if you need any assistance.
Here you can find an overview of all our applications. Reach out to us if you need any assistance.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Suspendisse varius enim in eros elementum tristique. Duis cursus, mi quis viverra ornare, eros dolor.
In this section home owners with an interest in our Cell String Optimizer technology can find all information about our technology and applications. Please refer to our contact page if there are any further questions.
Please browse our FAQ for all questions regarding our Cell String Optimizer. This section focusses on question from home owners
Taylor supplies solar panels with integrated electronics. The integrated electronic components optimize the output of them module per cell string, which we call Cell String Optimization. This results in a higher output per solar panel in case of shadow on the panel (up to 20%).
Cell String Optimization does not only improve the output in shading conditions, but also reduces the effects of cell degradation over time. Besides that it eliminates the possibility of hotspot issues.
Safe voltage
taylor. modules only provide power when necessary, following Sunspec protocol. If you power down the gateway, your solar panel will only produce 1 volt per panel. This also means that during installation or maintenance, the solar panels have a safe voltage.
Less MC4 connectors neededWith integrated CSO’s less MC4 connectors are needed, which lowers install costs & risk of installation mistakes.
Overtemperature
Overtemperature protection and module-level shutdown lowers (fire) risk."
A typical solar module exist of 3 (or 6) Cell Strings. A cell string is a row of solar cells connect in series to each other. With Cell String Optimization taylor modules are able to maximize the output of every Cell String specifically using integrated taylor electronics, resulting in more power in shading conditions and during cell degradation over a period of time.
You system consist of two main components; the CSO and your Gateway.
After your installation team is done installing your solar panels, a registration mail should automatically be send to your email. If you did not receive an email, please contact your installer, and have them double check the if the mail adres is correctly entered in the system. If this does not solve the issue, please send an email to: support@taylor.solar. Please include your adres & the name of the installer.
If you did receive the email, but still have trouble logging in, try the "wachtwoord vergeten" option in the page "dashboard.taylor.solar", to set a new password.
In case both options do not work, please contact your installer.
At this moment it is not possible to adjust energy prices in your dashboard. This is currently being developed and will soon be possible.
In your dashboard you will see a basic overview of the current status and energy output of your system. Below are the main components explained.
Reach out to us if you need any assistance