How many panels can I connect in 1 string per MPP tracker on my inverter?

Below table shows information on the amount of panels you can or should use per MPPT on your inverter. Maximum amount of panels is depended on your maximum input voltage of your inverter, minimum amount of panels needed is depended on your minimum MPPT voltage.


Note that:

  1. Below voltages are temperature corrected from Standard Test Conditions (STC). E.g. clouds create a scenario below 1000W/m2, which lowers your total system voltage.
  2. In shadow situations (e.g. chimney close to the panels), take a higher number for minimum amount of panels to make sure your system works optimal.
  3. With a taylor system, only connect 1 string per MPP tracker to your inverter. It is not possible to use 2 strings per MPP tracker.

*all systems and environments are unique, below is a guideline which needs adjustment per case. In case of any doubt contact our support department, we are happy to help.

* The above numbers are based on corrected Standard Test Conditions (STC) values > (STC: 1000W/m2 & 25C)

* For the maximum voltage scenario, the total system voltage is calculated at -15C.

* For the minimum voltage scenario, the total system voltage is calculated at +80C.